E-CODE 2099
UnclassifiedElectrical
What This Code Means
Voltage measures more than 40 VAC between Wire 194/Wire 23 and Wire 0
Possible Causes
- •Mis-wired connection at TB1 & TB2 or in the transfer switch
Suggested Actions
- 1Find the mis-wired connection at TB1 & TB2 or in the transfer switch
- 2Power cycle the controller and retest, if still present replace the controller and retest