ALARM #10

UnclassifiedElectrical

What This Code Means

Problem persists after turning batteries off and restarting equipment; An error occurred in one of the inverters; An error occurred in the communication of one of the inverters; Error LEDs are on (red); Battery error persists after restarting; Battery state of charge is low (30%, 25%, or 21%); Operating mode will shut down when battery charge reaches 20%; The equipment has shut down; One of the devices assumed the master state; Firmware incompatibility

Possible Causes

  • Problem in the Cerbo GX
  • Problem in one of the inverters
  • Broken maintenance disconnector
  • L1 inverter has stopped working
  • One of the inverters has stopped working
  • Defective battery
  • Deterioration of battery cells
  • Problem in communication in battery modules
  • Low battery state of charge
  • One of the phases has been disabled
  • The original master failed
  • The firmware of one of the connected devices is not up-to-date enough to work with this device

Suggested Actions

  1. 1Turn the batteries off and restart the equipment
  2. 2Refer to the manual to perform a system shutdown (do not turn the batteries off)
  3. 3Check that the communication between the inverters is correct, especially the L1 inverter
  4. 4Check that the RJ45 connectors of the L1 inverter are in good condition and tight
  5. 5Check that the voltage between the DC terminals of the L1 inverter input is correct
  6. 6Replace the maintenance disconnector
  7. 7Check that the communication between the inverters is correct
  8. 8Check that the RJ45 connectors of the inverters and the Cerbo GX are in good condition and tight
  9. 9Check that the batteries are working properly
  10. 10Identify which battery is defective
  11. 11Charge the battery as soon as possible