AUXILIARY SWITCH FAULT
UnclassifiedSensors
What This Code Means
Position-indicating contacts indicate ATS position changed when no transfer was called for; Both auxiliary switches are open or closed simultaneously; Controller unable to determine transfer switch position; Transfer switch in Normal position executes Engine Cooldown time delay and opens engine start contacts to stop generator set
Possible Causes
- •Both auxiliary switches are open or closed
- •Both auxiliary switches are open or closed so that the controller is unable to determine the transfer switch position
- •Both auxiliary switches are open or closed so the controller is unable to determine transfer switch position
- •Both auxiliary switches in the same state (both open or both closed)
- •Controller cannot determine the transfer switch position
- •Main shaft auxiliary switch error indicating multiple positions
- •Main shaft auxiliary switches indicate that the ATS is in more than one position
- •Position changed when no signal was sent to initiate the change
- •Position-indicating contacts indicate ATS position changed when controller did not send a signal to transfer
- •Position-indicating contacts indicate ATS position changed when no transfer was called for
- •Position-indicating contacts indicate that the ATS position changed when no transfer was called for
- •Transfer switch in intermediate position
- •Uninitiated ATS position change
- •Unsolicited ATS position change detected by position-indicating contacts
Suggested Actions
- 1Check the control contact operation
- 2Check the control contact operation.
- 3Check wiring and connections to position microswitches (see schematic drawing)
- 4Check wiring and connections to position microswitches.
- 5Check wiring and connections to position microswitches. See schematic drawing for connections
- 6Contact an authorized distributor/dealer for service if the fault persists
- 7Identify and correct the cause of the fault condition
- 8Inspect for signs of coil damage or overheating and replace coil if necessary
- 9Inspect for signs of coil damage or overheating and replace coil if necessary.
- 10Manually operate the transfer switch following safety precautions and instructions
- 11Manually operate the transfer switch, following safety precautions and instructions for your model
- 12Manually operate the transfer switch, following safety precautions and instructions for your model.
- 13Replace microswitch if necessary
- 14Replace microswitch if necessary.
- 15Reset the controller to clear the fault condition
- 16Reset the controller to clear the fault condition (press and hold the test and exercise pushbuttons simultaneously to clear fault and silence alarm)
- 17Reset the fault condition as described in Section 4.4.1
- 18Test position microswitch operation
- 19Test position microswitch operation.
- 20Test position microswitch operation. Replace microswitch if necessary