359
UnclassifiedCooling
What This Code Means
Coolant level sensor signal is showing a low coolant level for greater than 10 seconds; Engine failed to start after the expiration of crank time; Engine oil pressure is below the low oil pressure shutdown threshold; Low Coolant Level warning message; Low Coolant Level shutdown message; Engine coolant level has fallen below the trip point; Fail To Start shutdown message; Engine cranks but fails to start; Engine oil pressure has dropped below the shutdown trip point
Possible Causes
- •Low coolant
- •Fuel system issues
- •Manual fuel shutoff (FSO) valve is closed
- •FSO valve solenoids or circuit are malfunctioning
- •Incorrect starter disconnect speed
- •Lubricating oil level is low
- •Coolant leakage
- •Low coolant level
- •Fault with the control system
- •Fault with the starting system
- •Empty fuel tank
- •Fuel leaks
- •Blocked fuel lines
- •Dirty fuel filter
- •Dirty air filter
- •Blocked air filter
- •Loose battery cable connections
- •Discharged battery
- •Defective battery
- •Faulty oil filters
Suggested Actions
- 1Remove radiator cap and check that coolant is up to the required level
- 2Inspect fuel lines and fuel connections for leaks and repair if found
- 3Open the manual fuel shutoff (FSO) valve
- 4Check the FSO valve solenoids and circuit, and correct or replace as necessary
- 5Connect to the control via the InPower service tool and make sure Starter Disconnect Speed is set to 400 RPM
- 6Allow the engine to cool down completely before proceeding
- 7Look for possible coolant leakage points and repair if necessary
- 8Check coolant level and replenish if low
- 9Reset the control and restart after locating and correcting the problem
- 10Allow the engine to cool down completely before proceeding with checks
- 11Check for an empty fuel tank, fuel leaks, or blocked fuel lines and correct as required
- 12Check for a dirty fuel filter and replace if necessary
- 13Check for a dirty or blocked air filter and replace if necessary
- 14Clean and tighten all battery cable connections
- 15Recharge or replace battery
- 16Reset the control and restart after correcting the problem
- 17Check the oil level, lines and filters
- 18Replenish oil if the oil level is low
ASK RUDY ABOUT THIS FAULT
Get a diagnosis walkthrough for 359 on your specific Cummins unit — cited to the OEM manual, not a forum guess.
TRY IT FREE