1070

UnclassifiedGeneral

What This Code Means

Insufficient air flow

Possible Causes

  • •"Off" was pressed when the "Small Fan Failure" Warning was present
  • •"Off" was pressed when the "Small Fan Failure" Warning was present (Ecode 1070)
  • •Brushes incorrectly wired
  • •Incorrectly wired
  • •Insufficient air flow
  • •Off was pressed when the Small Fan Failure Warning was present
  • •Off was pressed when the Small Fan Failure Warning was present (Ecode 1070)
  • •One of the fans is blocked or not working
  • •The brushes are arcing or worn
  • •The generator was severely overloaded (shorted)
  • •The rotor is shorted

Suggested Actions

  1. 1Check AVR Air flow for restriction
  2. 2Check for Overload conditions
  3. 3Perform Auxiliary Power Supply test
  4. 4Perform Large Fan Test
  5. 5Perform Rotor Brush Test
  6. 6Perform Small fan test
  7. 7Check for proper fuel supply and settings must be within specifications of unit
  8. 8Check for proper fuel supply and settings within specifications of unit
  9. 9Check fuel supply and fuel pressure
  10. 10Check harness connections to AVR
  11. 11Check rotor resistance at slip rings
  12. 12Check stepper operation
  13. 13Inspect harness
  14. 14Open MLCB and retest unit
  15. 15Perform Power Winding and DPE tests
  16. 16Perform Power Winding and DPE winding tests
  17. 17Perform stepper motor test