NOEC
UnclassifiedEmissions
What This Code Means
NoEC Fault on the RDC/DC Controller; Controller resetting to default parameters
Possible Causes
- •Connecting or disconnecting battery cables without removing fuse F3 prior
- •Controller parameters lost or reset to default settings
- •Installation of a service replacement controller requiring initial parameter setup
- •Missing engine configuration settings
- •Power to controller momentarily connected and disconnected (e.g., when connecting/disconnecting battery during installation or service)
Suggested Actions
- 1Change the Ec parameter to the appropriate model setting (Ec13 for 14RES/RESL, Ec14 for 20RES/RESL)
- 2Check and adjust the Uu setting if necessary (Uu01 for 60 Hz 120/240V, Uu06 for 50 Hz 115/230V)
- 3Configure required controller parameters using RDC keypad or Kohler SiteTech software to clear NoEC fault
- 4Do not replace the controller
- 5For Models 14/20RES: Use RDC controller keypad or Kohler SiteTech software to set parameters
- 6For Models 14/20RESL: Use Kohler SiteTech software to set parameters on the DC controller
- 7Remove controller fuse F3 before disconnecting or reconnecting battery cables to prevent parameter reset
- 8Remove fuse F3 prior to disconnecting or reconnecting battery cables
- 9Set Engine Configuration Parameters (Ec13 for 14RES / 14RESL or Ec14 for 20RES / 20RESL models)
- 10Set System Voltage and Frequency Parameters (Uu01 for 1 Phase, 60 Hz, 120/240 VAC or Uu06 for 1 Phase, 50 Hz, 115/230 VAC)
Related Rehlko Fault Codes