ALARM #37
UnclassifiedGeneral
What This Code Means
Equipment error; Error LEDs are on (red)
Possible Causes
- •Defective battery BMS
- •Defective safety contactor
- •Defective battery
- •One or more batteries must be updated
- •One or more batteries need attention
- •Defective elements
Suggested Actions
- 1Check that the communication between the BMS of the batteries and the Cerbo GX is correct
- 2Check that the RJ45 connectors connected between the battery modules are in good condition and tightly tightened
- 3Check the voltage between the DC bus from the EHR
- 4Turn the batteries off and restart the equipment
- 5Replace defective modules
- 6Refer to the manual to perform a system shutdown (do not turn the batteries off)
- 7Check that the RJ45 connectors are in good condition and tightly tightened
- 8Check that the batteries are working properly
- 9Identify which battery is defective by checking the red error LEDs
- 10Call technical support to perform the upgrade
- 11Identify the defective elements by checking if the red error LEDs are on