8904

UnclassifiedGeneral

What This Code Means

MIL ON during active fault; Closed Loop Disabled

Possible Causes

  • UEGO internal supply voltage is low
  • Power is noisy due to a failed alternator
  • Supply voltage problem
  • ECM is unable to monitor the noise via the low-passed supply feedback
  • UEGO processing circuitry supply voltage is too low for normal operation (while Vbat or Vrelay low-pass filtered voltage is > 9.0V)
  • Noisy power due to a failed alternator
  • ECM is unable to monitor noise via low-passed supply feedback

Suggested Actions

  1. 1Replace ECM and re-test
  2. 2Inspect alternator and repair/replace as needed
  3. 3Troubleshoot supply voltage source; repair/replace as needed
  4. 4Replace UEGO sensor and re-test

Related Power Solutions International Fault Codes