Fault Codes/Power Solutions International/342Power Solutions International342UnclassifiedGeneralWhat This Code MeansMIL ON during active fault; Engine shutdownPossible Causes•No camshaft signal received for 2.5 engine cycles with engine speed greater than 1000 RPM while receiving valid crankshaft position data•Camshaft position sensor is not securely connected to the harness•Camshaft position sensor is not securely installed, or bracket is loose/misaligned•Open circuit in the camshaft position sensor circuit wiringSuggested Actions1Check that the camshaft position sensor is securely connected to harness2Check that the camshaft position sensor is securely installed, and bracket (if used) is tight and properly aligned with the crankshaft position wheel3Check camshaft position sensor circuit wiring for open circuitRelated Power Solutions International Fault Codes563652337685336891 432710223261023302 91025Browse all Power Solutions International fault codes→ASK RUDY ABOUT THIS FAULTGet a diagnosis walkthrough for 342 on your specific Power Solutions International unit — cited to the OEM manual, not a forum guess.TRY IT FREE