Fault Codes/Power Solutions International/302 9Power Solutions International302 9UnclassifiedGeneralWhat This Code MeansMalfunction Indicator Lamp (MIL) ON; Adaptive disabledPossible Causes•Faulty UEGO sensor•UEGO drift compensation accumulator exceeds maximum positive or negative thresholds (< -12.0% lp or > 12.0% lp)Suggested Actions1Replace the UEGO sensor2Clear the codeRelated Power Solutions International Fault Codes326327302 4336223337222342161 4563123652Browse all Power Solutions International fault codes→ASK RUDY ABOUT THIS FAULTGet a diagnosis walkthrough for 302 9 on your specific Power Solutions International unit — cited to the OEM manual, not a forum guess.TRY IT FREE