27

UnclassifiedElectrical

What This Code Means

Overcurrent warning; Overcurrent shutdown; High AC voltage; Output voltage on any phase exceeds pre-set values; Low AC voltage; Voltage on any phase has dropped below a pre-set value; Utility failure; High AC voltage shutdown; Low AC voltage shutdown; Voltage on any phase drops below a pre-set value; Overcurrent; Generator shutdown; Current level reaches instantaneous trip level or violates thermal damage curve; Utility failure detection unavailable; Automatic mains failure (AMF) feature not functioning; Unable to use AMF (Automatic Mains Failure) feature on the 1302 control; Current exceeds calculated instantaneous trip level; Overcurrent condition; Voltage on any phase dropped below a pre-set value; Emergency stop; Voltage on any phase drops below pre-set value; Overcurrent warning/shutdown; Mains failure; Inability to use the Automatic Mains Failure (AMF) feature on the 1302 control; Inability to use Automatic Mains Failure (AMF) feature on the 1302 control; Generator set starts/sto

Possible Causes

  • •Current exceeds instantaneous trip level calculated based on current transformer ratio and application power rating
  • •Current exceeds thermal damage curve
  • •Current exceeds thermal damage curve limit
  • •Current exceeds thermal damage curve or instantaneous trip level
  • •Current exceeds thermal damage curve or instantaneous trip level calculated based on current transformer ratio and application power rating
  • •Current level exceeds the instantaneous trip level calculated based on the thermal damage curve, current transformer ratio, and application power rating
  • •Excitation Fault (Loss of Voltage Sense)
  • •Instantaneous trip level exceeded based on current transformer ratio and application power rating
  • •Loss of utility power source
  • •Loss of voltage or frequency sensing from the generator
  • •Output voltage on any phase exceeds pre-set values
  • •Output voltage on any phase exceeds pre-set values (105-130% of nominal voltage)
  • •Output voltage on any phase exceeds pre-set values (adjustable from 105-130% of nominal voltage)
  • •Thermal damage curve exceeded
  • •Thermal damage curve limit exceeded
  • •Thermal damage curve limit or instantaneous trip level exceeded based on current transformer ratio and application power rating
  • •Utility failure
  • •Utility power outage or failure
  • •Voltage on any phase drops below pre-set value (50-95% of reference voltage)
  • •Voltage on any phase drops below pre-set value (adjustable over a range of 50-95% of reference voltage)
  • •Voltage on any phase has dropped below a pre-set value
  • •Voltage on any phase has dropped below a pre-set value (adjustable over a range of 50-95% of reference voltage)

Suggested Actions

  1. 1AMF feature automatically starts the generator set
  2. 2AMF feature provides automatic transfer of the load from utility to generator set
  3. 3Adjust time delay within 0.1-10 seconds
  4. 4Adjust time delay within 2-20 seconds
  5. 5Adjust voltage threshold settings within 105-130% of nominal voltage
  6. 6Adjust voltage threshold settings within 50-95% of reference voltage
  7. 7Automatic start and stop of the generator set
  8. 8Automatic start-stop of the generator set
  9. 9Automatic transfer and re-transfer of the load from utility to generator set and vice-versa
  10. 10Automatic transfer and re-transfer of the load from utility to generator set via built-in AMF feature
  11. 11Automatic transfer and re-transfer of the load from utility to generator set via the built-in AMF feature
  12. 12Automatically start and stop the generator set
  13. 13Automatically starts-stops the generator set
  14. 14Connect a utility voltage monitoring sensor to the 1302 control
  15. 15High AC voltage shutdown (trips after delay of 0.1 - 10 seconds; default 110% for 10 seconds)
  16. 16High AC voltage shutdown (with adjustable time delay from 0.1 - 10 seconds)
  17. 17Low AC voltage shutdown (trips after delay of 2-20 seconds; default 85% for 10 seconds)
  18. 18Low AC voltage shutdown (with adjustable time delay from 2-20 seconds)
  19. 19Overcurrent shutdown
  20. 20Overcurrent warning