129
UnclassifiedLubrication
What This Code Means
DST displays BP less than defined in the diagnostic calibration; BP Low Pressure
Possible Causes
- •Intermittent problem
- •Poor connection at sensor
- •Faulty MAP sensor
- •Faulty Harness
Suggested Actions
- 1Perform the On-Board (OBD) System Check
- 2Disconnect MAP sensor from harness and jumper the MAP circuit to 5Vref 1 (5 VDC) in connector on harness
- 3Disconnect wire harness header from ECM, remove yellow lock from header at device output terminal, and check resistance between MAP input at ECM header and signal at device
- 4Probe MAP signal circuit with a test light connected to battery voltage
- 5Perform On-Board (OBD) System Check
- 6Disconnect wire harness header from ECM and check resistance between MAP input at ECM header and signal at device
- 7Disconnect MAP sensor from harness, jumper the MAP circuit to 5Vref 1 (5 VDC) in connector on harness, and check if DST displays BP > 14.0 psia
- 8Probe MAP signal circuit with a test light connected to battery voltage and check if DST displays BP > 14.0 psia