1171

UnclassifiedGeneral

What This Code Means

MIL (Malfunction Indicator Light) ON during active fault; Adaptive learn disabled; Engine shutdown

Possible Causes

  • EPR actual pressure is greater than 1.5 inches water pressure above commanded pressure
  • EPR electrical connector pins C018 damaged, corroded, or contaminated
  • EPR failing fuel pressure test specifications
  • Electronic Pressure Regulator (EPR) internal circuitry fault
  • Faulty EPR (Engine Pressure Regulator)
  • Faulty wiring harness/circuit
  • High fuel pressure into the EPR

Suggested Actions

  1. 1Clear DTC information from the ECM using the DST, turn the ignition OFF for 30 seconds, and operate the engine to full operating temperature to verify the repair.
  2. 2Inspect the EPR electrical connector pins C018 for damage, corrosion, or contamination and repair the circuit as necessary.
  3. 3Perform the On-Board (OBD) System Check.
  4. 4Replace or repair the EPR.
  5. 5Run the EPR pressure test in the fuel system diagnostic section and follow EPR service recommendations from the fuel pressure test chart.
  6. 6Run the fuel pressure diagnostic test in the fuel system diagnostic section.
  7. 7Run the fuel system diagnostic pressure check
  8. 8Verify if DTC 1171 or 1172 are triggered; if so, refer to the appropriate section for diagnostic information