GO OFFLINE FOR REGEN WARNING
UnclassifiedGeneral
What This Code Means
Hydrocarbon (HC) buildup over 50%; Hydrocarbon (HC) levels need to be reduced
Possible Causes
- •Hydrocarbon (HC) buildup on Tier 4 generator set during operation
Suggested Actions
- 1Generate 'Go Offline for Regen Warning' on APM603 controller
- 2Shed generator set load and take offline within 90 seconds
- 3Activate load bank once generator set goes offline
- 4Activate load bank if paralleling breaker is open
- 5Activate load bank if generator is the only unit online and total load including load bank will not exceed 90% of generator rated power
Related Rehlko Fault Codes