AUX
UnclassifiedGeneral
What This Code Means
Audiovisual alarm or common fault relay activated on Common fault/prealarm line 1 (Terminal 32); Audiovisual alarm or common fault relay activated on Common fault/prealarm line 2 (Terminal 32A)
Possible Causes
- •AHET (Anticipatory high engine temperature) fault
- •ALOP (Anticipatory low oil pressure) fault
- •AUX (Auxiliary) fault
- •AUX Fault
- •AUX Fault (Auxiliary)
- •AUX condition
- •AUX faults
- •Anticipatory high engine temperature (AHET) fault
- •Anticipatory high engine temperature (AHET) fault (Terminal 40)
- •Anticipatory high engine temperature (AHET) prealarm
- •Anticipatory high engine temperature fault (AHET, terminal 40)
- •Anticipatory low oil pressure (ALOP) fault
- •Anticipatory low oil pressure (ALOP) fault (Terminal 41)
- •Anticipatory low oil pressure (ALOP) prealarm
- •Anticipatory low oil pressure fault (ALOP, terminal 41)
- •Auxiliary (AUX)
- •Auxiliary (AUX) Fault
- •Auxiliary (AUX) fault
- •Auxiliary (AUX) fault (Terminal 26)
- •Auxiliary (AUX) faults
- •Auxiliary fault (AUX)
- •Auxiliary fault (AUX, terminal 26)
- •Battery charger fault
- •Batterycharger fault
- •Batterychargerfault
- •ES (Emergency stop) fault
- •Emergency stop (ES) fault (Terminal 48)
- •Emergency stop fault (ES, terminal 48)
- •HET (High engine temperature) fault
- •HET Fault
- •HET Fault (High Engine Temperature)
- •HET condition
- •High Engine Temperature (HET)
- •High Engine Temperature (HET) Fault
- •High Engine Temperature fault (HET)
- •High engine temperature (HET) fault
- •High engine temperature (HET) fault (Terminal 36)
- •High engine temperature fault (HET, terminal 36)
- •LF (Low fuel) fault
- •LOP (Low oil pressure) fault
- •LOP Fault
- •LOP Fault (Low Oil Pressure)
- •LOP condition
- •LWT (Low water temperature) fault
- •LWT Fault
- •LWT Fault (Low Water Temperature)
- •LWT condition
- •Low Oil Pressure (LOP)
- •Low Oil Pressure (LOP) Fault
- •Low Oil Pressure fault (LOP)
- •Low Water Temperature (LWT)
- •Low Water Temperature (LWT) Fault
- •Low Water Temperature condition
- •Low Water Temperature fault (LWT)
- •Low Water Temperature/Level (LWT)
- •Low battery voltage
- •Low battery volts
- •Low coolant/water temperature detected
- •Low fuel
- •Low fuel (LF) fault
- •Low fuel (LF) fault (Terminal 63)
- •Low fuel fault (LF, terminal 63)
- •Low fuel level
- •Low oil pressure (LOP) fault
- •Low oil pressure (LOP) fault (Terminal 38)
- •Low oil pressure fault (LOP, terminal 38)
- •Low water temperature
- •Low water temperature (L WT) fault
- •Low water temperature (LWT) fault
- •Low water temperature (LWT) fault (Terminal 35)
- •Low water temperature fault (L WT, terminal 35)
- •OC (Overcrank) fault
- •OC Fault
- •OC Fault (Overcrank)
- •OC condition
- •OC, AUX, LWT, HET, LOP, OS, AHET, ALOP, and LF faults
- •OS (Overspeed) fault
- •OS Fault
- •OS Fault (Overspeed)
- •OS condition
- •Overcrank (OC)
- •Overcrank (OC) Fault
- •Overcrank (OC) fault
- •Overcrank (OC) fault (Terminal 12)
- •Overcrank fault (OC)
- •Overcrank fault (OC, terminal 12)
- •Overspeed (OS)
- •Overspeed (OS) Fault
- •Overspeed (OS) fault
- •Overspeed (OS) fault (Terminal 39)
- •Overspeed fault (OS)
- •Overspeed fault (OS, terminal 39)
Suggested Actions
- 1Activate audiovisual alarm or common fault relay
- 2Connect A/V Alarm or Common Fault Relay Kit
- 3Connect A/V Alarm or Common Fault Relay Kit to terminal TB1-32
- 4Connect AV Alarm or Common Fault Relay Kit
- 5Connect LWT Sensor (Prealarm Kit) to TB1-35 to activate LWT or LWT/AUX lamp
- 6Connect LWT Sensor (Prealarm Kit) to terminal TB1-35
- 7Connect a remote annunciator and/or audiovisual alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1.
- 8Connect battery charger alarm contact to TB1-61 to activate fault lamp (activelow) (if used).
- 9Connect battery charger alarm contact to TB1-62
- 10Connect battery charger alarm contact to TB1-62 to activate fault lamp (activelow) (if used).
- 11Connect batterycharger alarm contact to TB1-61
- 12Connect fuel level sensor to TB1-63
- 13Connect fuel level sensor to TB1-63 to activate fault lamp (activelow) (if used).
- 14Use a remote annunciator and/or A/V alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1
- 15Use a remote annunciator and/or audiovisual alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1
Related Rehlko Fault Codes
ASK RUDY ABOUT THIS FAULT
Get a diagnosis walkthrough for AUX on your specific Rehlko unit — cited to the OEM manual, not a forum guess.
GET THE ANSWER
Free account required — we'll bring your question with you.