7452-040

UnclassifiedAir Intake

What This Code Means

The entire screen on the service indicator becomes red; Restriction of the air flowing through the air filter reaches 762 ± 6 mm (30 ± 2.3 inches) H2O; Service indicator has cracks; Service indicator has holes; Service indicator has loose fittings; Service indicator does not reset in three pushes or less; Service indicator plunger does not move when starting the engine

Possible Causes

  • •Air cleaner element is dirty
  • •Debris entering the indicator mechanism
  • •Defective service indicator
  • •Hole for the service indicator is plugged
  • •Using paint, a waterproof cover, or plastic as a protective covering for storage of primary air cleaner elements

Suggested Actions

  1. 1Clean the air cleaner element
  2. 2Do not use paint, a waterproof cover, or plastic as a protective covering
  3. 3Inspect and clean the porous filter using compressed air or a clean nonflammable solvent
  4. 4Place the primary air cleaner element into a box for storage
  5. 5Replace the air cleaner element
  6. 6Replace the service indicator
  7. 7Replace the service indicator and torque the fitting to 2 N·m (18 lb in)
  8. 8Wrap the primary air cleaner elements in Volatile Corrosion Inhibited (VCI) paper