219

UnclassifiedGeneral

What This Code Means

CHARGER FAILURE warning displayed; Battery charging alternator not reaching acceptable voltage within time limit

Possible Causes

  • •Alternator does not support charging alternator functionality while Charging Alt feature is enabled
  • •Alternator type does not support the control's charging alternator logic functionality
  • •Battery charging alternator did not reach acceptable voltage range within selected time period (default = 120 seconds)
  • •Charger failure warning setting is not set to "No"
  • •Charging alternator voltage reaches or drops to the Charger Failed L Threshold for the duration of the time delay
  • •Charging alternator voltage reaches or exceeds the Charger Failed H Threshold for the duration of the time delay

Suggested Actions

  1. 1Change the Charging Alt setting to 'No'
  2. 2Change the setting to "No" to disable the Charger Failure warning
  3. 3Disable warning by setting 'Charging Alt. Enable' setting to 'No' in Genset Service submenus (page 5-8) if alternator does not support charging logic

ASK RUDY ABOUT THIS FAULT

Get a diagnosis walkthrough for 219 on your specific Cummins unit — cited to the OEM manual, not a forum guess.

GET THE ANSWER

Free account required — we'll bring your question with you.