187

UnclassifiedElectrical

What This Code Means

DST displays FT voltage less than the limit defined in calibration; DST displays FT voltage of 0.1 or less when FT sensor is disconnected

Possible Causes

  • Intermittent problem (operating condition dependent)
  • Faulty FT sensor
  • Sensor signal circuit shorted to ground
  • Faulty ECM

Suggested Actions

  1. 1Perform the On-Board (OBD) System Check
  2. 2With Key ON, Engine Running and System Mode = 'Running', check if DST displays FT voltage less than the limit defined in calibration
  3. 3With Key OFF, Key On, Engine Off and System Mode = 'Stopped', wait for fuel pump to stop running, disconnect FT sensor from harness, and check if DST displays FT voltage of 0.1 or less
  4. 4Check wire harness for ground short