1351
UnclassifiedGeneral
What This Code Means
MIL: ON; Engine Shutdown; Ignition/spark drive circuitry (internal to the ECM) is overheating
Possible Causes
- •Adaptive dwell is disabled
- •Ambient conditions exceeding 85C on a continuous basis or 125C for short intervals
- •Ambient conditions exceeding 85°C on a continuous basis or 125°C for short intervals
- •Ambient temperatures exceeding 85C continuously or 125C for short intervals
- •Charring or arcing around the spark plugs
- •Coil resistance out of specifications
- •Dwell time set too long in diagnostic calibration
- •Dwell time set too long in the diagnostic calibration
- •Ignition/spark drive circuitry (internal to the ECM) is overheating
- •Incorrect plug gap
- •Incorrect plug gap on the associated cylinder
- •Loose connections at the coil and spark plugs
- •Low-quality coils with a history of internal arcing or other failures
- •Short internal to the coil
- •Spark plug or coil failure
- •Use of low-quality coils with a history of internal arcing or other failures
Suggested Actions
- 1Check coil resistance and verify that it is within specifications
- 2Check coil resistance and verify that it is within specifications.
- 3Check for loose connections at the coil and spark plugs
- 4Check for loose connections at the coil and spark plugs.
- 5Check plug gap on the cylinder associated with the fault
- 6Check plug gap on the cylinder associated with the fault.
- 7Ensure the use of high-quality coils without a history of internal arcing or other failures
- 8Ensure the use of high-quality coils without a history of internal arcing or other failures.
- 9Look for a short internal to the coil
- 10Look for a short internal to the coil.
- 11Look for evidence of charring or arcing around the spark plugs
- 12Look for evidence of charring or arcing around the spark plugs.
- 13Verify that adaptive dwell is enabled
- 14Verify that ambient conditions are not exceeding 85C on a continuous basis or 125C for short intervals, and verify if the fault stops occurring when ambient temperatures are lower
- 15Verify that ambient conditions are not exceeding 85C on a continuous basis or 125C for short intervals.
- 16Verify that ambient conditions are not exceeding 85°C on a continuous basis or 125°C for short intervals, and check if the fault stops occurring when ambient temperatures are lower
- 17Verify that this fault stops occurring when ambient temperatures are lower.
- 18Verify the dwell time set in the diagnostic calibration is not set too long
- 19Verify the dwell time set in the diagnostic calibration is not set too long and that adaptive dwell is enabled
- 20Verify the dwell time set in the diagnostic calibration is not set too long and that adaptive dwell is enabled.