UNDERFREQUENCY
UnclassifiedGeneral
What This Code Means
Overfrequency fault or event message displayed; Underfrequency fault or event message displayed
Possible Causes
- •Frequency settings
- •Incorrect frequency settings
- •Loose source connections or wiring issues
- •Source availability or stability issues
- •Source availability, stability
- •Source connections
Suggested Actions
- 1Check for loose connections
- 2Check for loose connections and check wiring
- 3Check that the frequency debounce setting is long enough to prevent nuisance faults caused by brief frequency variations
- 4Check that the source frequency matches the nominal system frequency and stays within the range of the pickup and dropout settings
- 5Check that the system frequency setting matches the actual source frequency (50 or 60 Hz)
- 6Check the over/underfrequency pickup and dropout settings
- 7Check wiring
Related Discovery Energy, LLC (Rehlko) Fault Codes
ASK RUDY ABOUT THIS FAULT
Get a diagnosis walkthrough for UNDERFREQUENCY on your specific Discovery Energy, LLC (Rehlko) unit — cited to the OEM manual, not a forum guess.
GET THE ANSWER