SDC BAR 00 − 0AG
UnclassifiedGeneral
What This Code Means
High/Low AC Output (Genset); No AC Output (Genset)
Possible Causes
- •Broken or loose wires
- •Incorrect output lead wiring configuration
- •Faulty control connections at control
- •Faulty main rotor slip rings and brushes
- •Faulty main stator
- •Faulty control
- •Load breakers not closed
- •Faulty output to load breakers
- •Faulty field flash
- •Faulty output from AVR to brushes
- •Incorrect rotor winding resistance
- •Rotor winding grounded
- •Incorrect stator winding resistance
Suggested Actions
- 1Check for broken or loose wires
- 2Check output lead wiring configuration
- 3Check control connections at control
- 4Evaluate fault codes if present
- 5Check main rotor slip rings and brushes
- 6Check main stator
- 7Check load breakers closed
- 8Check output to load breakers
- 9Check AC output
- 10Check field flash
- 11Check control
- 12Check output from AVR to brushes
- 13Check rotor winding resistance
- 14Check if rotor winding is grounded
- 15Check stator winding resistance
Related Onan Fault Codes
ASK RUDY ABOUT THIS FAULT
Get a diagnosis walkthrough for SDC BAR 00 − 0AG on your specific Onan unit — cited to the OEM manual, not a forum guess.
TRY IT FREE