RPM SENSE LOSS
UnclassifiedStarting
What This Code Means
Unit was running and shut down, attempts to restart; Unit will not start in AUTO with utility loss
Possible Causes
- •Discharged or faulty battery
- •Excessive household loads on generator
- •Faulty battery or poor battery condition
- •Fuse problem
- •Loss of RPM sensor signal
- •Low oil pressure
- •Miswire
- •Overcrank
- •Overload
- •Overspeed
- •RPM sense loss
- •Stepper overcurrent
- •Underspeed
- •Undervoltage
Suggested Actions
- 1Attempt to start the unit in MANUAL.
- 2Check LEDs / screen for alarms.
- 3Check Oil Level/Add Oil Per Owners Manual.
- 4Check fuel line shutoff valve is in the ON position.
- 5Check the 7.5 Amp fuse.
- 6Check the LEDs / screen for alarms
- 7Check the battery using the control panel under the MAIN menu using the BATTERY MENU option.
- 8Clear alarm
- 9Clear alarm and remove household loads from generator.
- 10Clear alarm and remove household loads from the generator
- 11Clear alarm and remove household loads from the generator.
- 12Clear alarm.
- 13Contact servicing dealer.
- 14If battery condition displays GOOD, contact an IASD
- 15If battery condition displays GOOD, contact an IASD (Independent Authorized Service Dealer).
- 16If control panel displays CHECK BATTERY, replace the battery
- 17If generator does not start, contact an IASD
- 18If generator does not start, contact an IASD (Independent Authorized Service Dealer).
- 19If it does not start or starts and runs rough, contact servicing dealer.
- 20If it is bad replace it with an ATO 7.5 Amp fuse, if not contact servicing dealer.
- 21If it states CHECK BATTERY replace the battery.
- 22If it states battery is GOOD contact servicing dealer.
- 23If oil level is correct contact servicing dealer.
- 24Put back in AUTO and restart.
- 25Put generator into AUTO and restart.
- 26Put into AUTO and restart
- 27To clear an active alarm, press the OFF button, the EN TER button, and then press AUTO. If the alarm reoccurs, contact an IASD.
- 28Using control panel, check battery by navigating to BATTERY MENU option from MAIN MENU.
- 29Using the control panel, check the battery by navigating to the BATTERY MENU option from the MAIN MENU