OVERSPEED SHUTDOWN
What This Code Means
Overspeed shutdown; Engine running at an unsafe speed; Unit will not run; Engine shutdown; Engine pressure falls below 14.2 psi (98 kPa); Engine temperature exceeds 212° F (100° C); Engine fails to start after three cranking attempts; Engine engages at an unsafe speed; 1000 amp main breaker automatically trips; Loss of power to the Output Terminal Panel; Engine shuts down; Low Oil Pressure LED indicator active; High Coolant Temperature LED indicator active; Low coolant level LED indicator active; Loss of magnetic pickup LED indicator active; Engine failed to start; Overcrank Shutdown LED indicator active; Overspeed Shutdown LED indicator active; Overspeed Shutdown; Engine running at unsafe speed
Possible Causes
- •Engine running at an unsafe speed
- •Auto Start Stop Switch is set to the OFF/ RESET position
- •Oil pressure fell below 14.2 psi (98 kPa) detected via variable resistive values from the oil pressure sending unit
- •Engine temperature exceeded 212° F (100° C) detected via variable resistive values from the temperature sending unit
- •Engine fails to engage (start) by the third cranking attempt (pre-set at 10 seconds per attempt)
- •Engine is running at an unsafe speed (RPMs)
- •Low coolant level
- •Loss of magnetic pickup
- •Short circuit
- •Over current condition
- •Engine pressure has fallen below 15 psi
- •Engine temperature has exceeded 239 °F
- •Unit attempted to start a pre-programmed number of times and failed to start (pre-set at 3 cycles with a 10 second duration)
- •Engine is running at an unsafe speed
- •MPEC Control Switch is set to the OFF/RESET position
- •Engine running at unsafe speed
Suggested Actions
- 1Place the Auto Start Stop Switch in the manual position to start the generator immediately, or place it in the AUTO position to allow the automatic transfer switch (ATS) to start the generator automatically
- 2Press the reset button on the overcurrent relay
- 3Place the main circuit breaker in the closed position (ON)