MODULESTATUSCHANGE
UnclassifiedTransfer Switch
What This Code Means
ATS display shows ModuleStatusChange message; ATS display shows Check Module Setup to Clear Fault; Module Status Change message cannot be cleared
Possible Causes
- •One or more accessory modules are physically disconnected from the transfer switch controller
- •Failure of the controller's real-time clock
Suggested Actions
- 1Press Reset on the ATS display
- 2Press Main to return to the main screen
- 3Press Set to enter setup mode and enter the setup password
- 4Press the down arrow to step to the Set Inputs/Outputs screen
- 5Navigate to the Set Auxiliary I/O screen
- 6Press right arrow to view status of module 1 and step down until screen shows Status: Lost
- 7Press right arrow to move to Uninstall Module screen and verify screen displays Uninstall Module Yes
- 8Press Save to uninstall the module when Yes is displayed
- 9Repeat the uninstall procedure for additional modules if necessary
- 10Carefully follow Module Connection or Module Uninstall procedures to attempt to reset the fault
- 11Replace the controller's logic board if the fault cannot be reset
- 12Contact an authorized distributor/dealer for service