LOP
UnclassifiedCooling
What This Code Means
Common fault/prealarm line 1 activated; Common fault/prealarm line 2 activated; Fault lamp activated (activelow); Common fault/prealarm line activated; Fault lamp activated; Shutdown occurs if the engine coolant temperature exceeds the maximum temperature for more than 5 seconds; Shutdown occurs if a low oil pressure condition exists for more than 5 seconds; Shutdown occurs after 3 unsuccessful starting attempts; No engine rotation is sensed during cranking
Possible Causes
- •AHET (Anticipatory high engine temperature) fault
- •ALOP (Anticipatory low oil pressure) fault
- •AUX
- •AUX (Auxiliary) fault
- •AUX Fault
- •AUX Fault (Auxiliary)
- •AUX condition
- •AUX faults
- •Air cleaner clogged
- •Andere storing in het smeersysteem
- •Anticipatory high engine temperature (AHET) fault
- •Anticipatory high engine temperature (AHET) fault (Terminal 40)
- •Anticipatory high engine temperature (AHET) prealarm
- •Anticipatory high engine temperature fault (AHET, terminal 40)
- •Anticipatory low oil pressure (ALOP) fault
- •Anticipatory low oil pressure (ALOP) fault (Terminal 41)
- •Anticipatory low oil pressure (ALOP) prealarm
- •Anticipatory low oil pressure fault (ALOP, terminal 41)
- •Auxiliary (AUX)
- •Auxiliary (AUX) Fault
- •Auxiliary (AUX) fault
- •Auxiliary (AUX) fault (Terminal 26)
- •Auxiliary (AUX) faults
- •Auxiliary fault (AUX)
- •Auxiliary fault (AUX, terminal 26)
- •Battery Charger Fault (BATTERYCH.FAULT)
- •Batterycharger fault
- •Batterychargerfault
- •Blocked air inlets and exhaust outlets
- •Blown voltage regulator fuse
- •Clogged fuel filter
- •Closed LoP contacts placing ground on magneto
- •Defective fuel pump
- •Defective fuel solenoid
- •Défaillance de la pompe à huile
- •ES (Emergency stop) fault
- •Emergency Stop (E.STOP)
- •Emergency stop (ES) fault (Terminal 48)
- •Emergency stop fault (ES, terminal 48)
- •Engine fault (OC, OS, HWT, LOP, or LWL)
- •Engine fault switch closes to ground for 5 seconds
- •Engine fault switch closes to ground for 5 seconds after initial crank and start
- •Engine faults (OC, OS, HWT, LOP, LWL)
- •Fault shutdown condition (OC, OS, HWT, LOP, or LWL)
- •Fuel supply issue
- •Fuse blown in controller
- •HET (High engine temperature) fault
- •HET Fault
- •HET Fault (High Engine Temperature)
- •HET condition
- •HET switch closes to ground for 5 consecutive seconds
- •HIGH ENGINE TEMP fault switch closes to ground for >5 seconds
- •High Engine Temperature (HET)
- •High Engine Temperature (HET) Fault
- •High Engine Temperature fault (HET)
- •High engine temperature (HET) fault
- •High engine temperature (HET) fault (Terminal 36)
- •High engine temperature (HET) shutdown
- •High engine temperature fault (HET, terminal 36)
- •K5 relay energized closing contacts across remote start leads (RUN LATCH)
- •LF (Low fuel) fault
- •LOP (Low oil pressure) fault
- •LOP Fault
- •LOP Fault (Low Oil Pressure)
- •LOP condition
- •LOP switch closes to ground for 5 consecutive seconds
- •LOW OIL PRESS fault switch closes to ground for >5 seconds
- •LOW WATER LEVEL fault switch closes to ground for >5 seconds
- •LWL switch closes to ground for 5 consecutive seconds
- •LWT (Low water temperature) fault
- •LWT Fault
- •LWT Fault (Low Water Temperature)
- •LWT condition
- •Leaks in the lubrication system
- •Low Battery (LOWBATT.)
- •Low Coolant Level (LCL) shutdown
- •Low Fuel (LOWFUEL)
- •Low Oil (LO)
- •Low Oil Pressure (LOP)
- •Low Oil Pressure (LOP) Fault
- •Low Oil Pressure fault (LOP)
- •Low Water Temperature (LWT)
- •Low Water Temperature (LWT) Fault
- •Low Water Temperature fault (LWT)
- •Low Water Temperature/Level (LWT)
- •Low battery volts
- •Low coolant level (LCL) shutdown
- •Low engine oil level
- •Low fuel
- •Low fuel (LF) fault
- •Low fuel (LF) fault (Terminal 63)
- •Low fuel fault (LF, terminal 63)
- •Low oil level
- •Low oil pressure
- •Low oil pressure (LOP) fault
- •Low oil pressure (LOP) fault (Terminal 38)
- •Low oil pressure (LOP) shutdown
- •Low oil pressure condition
- •Low oil pressure condition exists for more than 5 seconds
- •Low oil pressure fault (LOP, terminal 38)
- •Low oil pressure in engine
- •Low water temperature (L WT) fault
- •Low water temperature (LWT) fault
- •Low water temperature (LWT) fault (Terminal 35)
- •Low water temperature fault (L WT, terminal 35)
- •OC (Overcrank) fault
- •OC Fault
- •OC Fault (Overcrank)
- •OC condition
- •OC, AUX, LWT, HET, LOP, OS, AHET, ALOP, and LF faults
- •OS (Overspeed) fault
- •OS Fault
- •OS Fault (Overspeed)
- •OS condition
- •Oil pressure falls below threshold
- •Oliepomp defect
- •Out of fuel
- •Overcrank (OC)
- •Overcrank (OC) Fault
- •Overcrank (OC) fault
- •Overcrank (OC) fault (Terminal 12)
- •Overcrank (oC)
- •Overcrank fault (OC)
- •Overcrank fault (OC, terminal 12)
- •Overcrank shutdown
- •Overspeed (OS)
- •Overspeed (OS) Fault
- •Overspeed (OS) fault
- •Overspeed (OS) fault (Terminal 39)
- •Overspeed fault (OS)
- •Overspeed fault (OS, terminal 39)
- •Overspeed shutdown
- •Problème de fonctionnement du moteur
- •Remote emergency stop switch activated
- •Run latch (K5 relay) preventing remote reset
- •SO
- •Spark plug issue
- •The LOP switch indicates low oil pressure for more than 5 seconds
- •Unit shutdown triggered by a fault condition (OC, OS, HWT, LOP, LWL)
Suggested Actions
- 1Activate audiovisual alarm or common fault relay
- 2Add coolant
- 3Add coolant. See Section 2. Operation and Generator Operation Manual
- 4Add oil if the level is low
- 5Check engine coolant level, loose fan belt, radiator obstructions, etc.
- 6Check engine coolant level, loose fan belt, radiator obstructions, etc. See Section 2. Operation & Generator Operation Manual
- 7Check engine lube oil level
- 8Check engine lube oil level. See Section 2. Operation & Generator Operation Manual
- 9Check for blocked air inlets and exhaust outlets
- 10Check for leaks in the lubrication system
- 11Check for loose connections
- 12Check the battery
- 13Check the engine oil level regularly as recommended in Section 3
- 14Check the fuel supply
- 15Check the oil level and add oil if the level is low
- 16Check the oil level at the engine
- 17Check the spark plug
- 18Clean or replace air cleaner element. See Generator Operation Manual
- 19Connect A/V Alarm or Common Fault Relay Kit
- 20Connect A/V Alarm or Common Fault Relay Kit to terminal TB1-32
- 21Connect AV Alarm or Common Fault Relay Kit
- 22Connect a remote annunciator and/or audiovisual alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1.
- 23Connect battery charger alarm contact to TB1-61 to activate fault lamp (activelow) (if used).
- 24Connect battery charger alarm contact to TB1-62
- 25Connect battery charger alarm contact to TB1-62 to activate fault lamp (activelow) (if used).
- 26Connect batterycharger alarm contact to TB1-61
- 27Connect fuel level sensor to TB1-63
- 28Connect fuel level sensor to TB1-63 to activate fault lamp (activelow) (if used).
- 29Contact an authorized distributor/dealer for service if problem continues
- 30Controleer het oliepeil regelmatig en vul olie bij als dat nodig is
- 31Correct the cause of failure
- 32Move Start/Stop Switch to the OFF/RESET position
- 33Move Start/Stop Switch to the Off/Reset position
- 34Operator must reset the fault at the generator by placing switch in OFF position
- 35Place selector switch in OFF/RESET position at the generator to reset the fault logic
- 36Replace air cleaner element
- 37Replace filter
- 38Replace filter. See Generator Operation Manual
- 39Replace fuse in controller
- 40Replace fuse. If fuse blows again, see Section 2. Operation and Section 5 or 6. Controller Troubleshooting
- 41Replace voltage regulator fuse
- 42Replenish fuel supply
- 43Reset at the generator controller by moving the Start / Stop switch to the OFF / RESET position
- 44Reset remote emergency stop switch (see Section 2. Operation)
- 45Reset the controller
- 46See Engine Service Manual
- 47See Section 2. Operation and Section 8. Component Testing
- 48Use a remote annunciator and/or A/V alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1
- 49Use a remote annunciator and/or audiovisual alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1
Related Rehlko Fault Codes
ASK RUDY ABOUT THIS FAULT
Get a diagnosis walkthrough for LOP on your specific Rehlko unit — cited to the OEM manual, not a forum guess.
GET THE ANSWER
Free account required — we'll bring your question with you.