LONG 1 SHORT 7

UnclassifiedCooling

What This Code Means

Low Oil Pressure; Starter Motor Protection active; Rotation Sensor Defective; Solenoid issue; Over Voltage; Rotation Sensor fault; Insufficient Charge; High Water Temperature; Engine Overheat, 230° F (110° C); Engine Overheat, 248° F (120° C); Emergency Stop; Starter Motor Protection; Solenoid fault; Water Temperature Sensor Disconnection; Water Temperature Sensor Short Circuit; Charging Gen. Terminal Disconnection

Possible Causes

  • Oil pressure 7 psi (49 kPa) or greater
  • Starter motor run for 12 seconds or more
  • Defective sensor
  • Short circuit
  • Defective solenoid
  • VCC 18 volts or greater
  • Oil pressure 7 psi (49 kPa) or greater?
  • No Voltage of Charging Genset?
  • Engine Overheat, 230° F (110° C)?
  • Engine Overheat, 248° F (120° C)?
  • Emergency Stop signal detected?
  • Starter motor run for 12 seconds or more?
  • Sensor disconnected
  • Terminal disconnection

Suggested Actions

  1. 1Check oil level.
  2. 2Check wiring and repair.
  3. 3Check overcurrent relay.
  4. 4Check cooling system.
  5. 5Check and repair fault
  6. 6Check connection.
  7. 7Check sensor.
  8. 8Replace.
  9. 9Check connections.