ES
UnclassifiedGeneral
What This Code Means
Audiovisual alarm or common fault relay activated on Common fault/prealarm line 2 (Terminal 32A); Emergency stop switch not functioning; Emergency stop relay (K4) inactive
Possible Causes
- •AHET (Anticipatory high engine temperature) fault
- •ALOP (Anticipatory low oil pressure) fault
- •AUX (Auxiliary) fault
- •Auxiliary (AUX) fault (Terminal 26)
- •Batterycharger fault
- •ES (Emergency stop) fault
- •Emergency stop (ES) fault (Terminal 48)
- •Emergency stop switch is not connected across terminals TB1-1 and 1A
- •Emergency stop switch is not used and no jumper is installed
- •HET (High engine temperature) fault
- •High engine temperature (HET) fault (Terminal 36)
- •LF (Low fuel) fault
- •LOP (Low oil pressure) fault
- •LWT (Low water temperature) fault
- •Low battery volts
- •Low oil pressure (LOP) fault (Terminal 38)
- •OC (Overcrank) fault
- •OS (Overspeed) fault
- •Open circuit across emergency stop terminals TB1-1 and 1A
- •Overspeed (OS) fault (Terminal 39)
Suggested Actions
- 1Activate audiovisual alarm or common fault relay
- 2Connect battery charger alarm contact to TB1-62
- 3Connect batterycharger alarm contact to TB1-61
- 4Connect emergency stop across terminals TB1-1 and 1A
- 5Connect fuel level sensor to TB1-63
- 6Connect jumper across terminals 1 and 1A
- 7Connect jumper across terminals 1 and 1A if emergency stop switch is not used
- 8Use a remote annunciator and/or audiovisual alarm kit as an indicator with a dry contact kit connected to controller terminal strip TB1