AC / DC DISPLAY ICON FLASHING
UnclassifiedStarting
What This Code Means
Unit does not have output power; Unit will not charge; Unit will not start; Unit starts, then shuts down
Possible Causes
- •Unit turned off
- •AC or DC output turned off
- •AC circuit breaker OPEN
- •Unit is overloaded
- •Unit temperature is below -4 °F (-20 °C)
- •Unit temperature is above 104 °F (40 C°)
- •AC or DC circuit error
- •Unit is defective
- •Bad power source
- •Loose connection
- •Unit temperature is below 32 °F (0 °C)
- •Unit temperature is above 104 °F (40 °C)
- •Defective charger
- •Power station powered ON incorrectly
- •Battery at 0% state of charge
- •No load present on unit
- •Display sleeps after 10 minutes
- •Power station automatically shuts down after 60 minutes to conserve battery
Suggested Actions
- 1Hold ON/OFF power button on the power station.
- 2Press AC or DC button to power on circuit.
- 3Reset circuit breaker.
- 4See Know Power Station Limits.
- 5Move power station inside to warm up. (This may take some time.)
- 6Move power station to cooler location. (This may take some time.)
- 7Hold AC or DC button for three (3) seconds to reset circuit.
- 8Contact IASD.
- 9Confirm power source is compatible with the power station.
- 10Check that plugs are firmly connected.
- 11Hold ON/OFF button for three (3) seconds to power ON the power station.
- 12Charge the power station.
- 13Hold ON/OFF button to power on the power station.