45

UnclassifiedCooling

What This Code Means

Soot deposits on EGR valve; EGR valve spool not moving freely; Heavy unburnt fuel (soot) deposits in the EGR valve; EGR valve is not commanded to open; Fault codes set in the ECU during restart attempts (after shutdown of any type)

Possible Causes

  • Light load soot deposits
  • Light loading situations
  • Small volume of air being used by the engine
  • Insufficient volume of cooler or denser air to mix with exhaust from the EGR without negatively affecting engine performance
  • Continuous operation of the unit under light load

Suggested Actions

  1. 1Remove the EGR valve by disconnecting one electrical plug and removing 7 bolts (gaskets can be reused)
  2. 2Remove unwanted deposits using a flat blade screwdriver
  3. 3Confirm the EGR valve spool moves freely after deposits are cleared
  4. 4Cycle the power (using the operator key or toggle switch) to self-clear the fault codes
  5. 5Remove the EGR valve (disconnect one electrical plug and 7 bolts) to clean off the soot deposits (Note: Gaskets can be reused)