1 SECOND FLASH (1 ON – 1 OFF)
UnclassifiedGeneral
What This Code Means
Module sheds its load; LED flashes at one second intervals
Possible Causes
- •Generator overload detected
- •Initial five minutes of operation during first-time utility power up
Suggested Actions
- 1Wait five minutes plus the predefined priority set time for the module to recover and contactor to close
- 2Set the priority of each SMM module (with high priority 240 VAC loads set to the highest priorities) so loads recover in the correct order and prevent generator overload
- 3Set the lockout switch to ENABLED for non-essential, non-critical loads that should not run on generator power